Specs at a glance
Process temperature
-52°C...+450°C (-61°F...+842°F)
Process pressure / max. overpressure limit
Field of application
The source container FQG74 is designed to reliably hold up to 20 internal radioactive sources with highest activities during radiometric measurements. Thanks to the robust and high shielding, the source container is easy to use in straight and bent dip tube.
The source container FQG74 is used in combination with a radiometric transmitter for point level detection, continuous level and multipoint density measurement. It is suitable for applications with long measuring ranges.
Oil & Gas
Petrochemical / Chemical
Benefits
Best-in-class safety (Type A approval) and radiation protection
Easy commissioning of the sources – the source position can be adjusted individually by independent ropes (maximal rope length: 30 meters)
High shielding ensures that no control areas are generally required and that installation in accessible areas is possible
A high versatility with different variants of the source container enables the use in multiple applications
Padlock for fixation the on/off switch position and to protect against theft
Xpert selection
Specialized products
Designed for demanding applications
Technical excellence
Simplicity
©Endress+Hauser
Simple products
Easy to select, install and operate
Technical excellence
Simplicity
Standard products
Reliable, robust and low-maintenance
Technical excellence
Simplicity
High-end products
Highly functional and convenient
Technical excellence
Simplicity
Specialized products
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections
Technical excellence
Simplicity
Fundamental selection
Meet your basic measurement needs
Technical excellence
Simplicity
Lean selection
Handle your core processes easily
Technical excellence
Simplicity
Extended selection
Optimize your processes with innovative technologies
Technical excellence
Simplicity
Xpert selection
Master your most challenging applications
Technical excellence
Simplicity
Loading alternative products
Success stories
Fit for purpose instrumentation for CNG compressors
The Egyptian government is working to replace liquid fuels with natural gas. To achieve this they targeted increasing the number of CNG stations in their country from 306 to 1000 by the end of 2021.
Read the full story
Characteristic / Application
Source container with flexible extension element to position up to 20 sources inside the process vessel (diptube) Weight: 800 kg
Specialities
With flexible extension elements
Ambient temperature
-52°C...+120°C, (-61°F...+248°F)
Process temperature
-52°C...+450°C (-61°F...+842°F)
Process pressure / max. overpressure limit
Characteristic / Application
Source container with flexible extension element to position up to 20 sources inside the process vessel (diptube) Weight: 800 kg
Specialities
With flexible extension elements
Ambient temperature
-52°C...+120°C, (-61°F...+248°F)
Process temperature
-52°C...+450°C (-61°F...+842°F)
Process pressure / max. overpressure limit
Characteristic / Application
Source container with flexible extension element to position up to 20 sources inside the process vessel (diptube) Weight: 800 kg
Specialities
With flexible extension elements
Ambient temperature
-52°C...+120°C, (-61°F...+248°F)
Process temperature
-52°C...+450°C (-61°F...+842°F)
Process pressure / max. overpressure limit
Characteristic / Application
Source container with flexible extension element to position up to 20 sources inside the process vessel (diptube) Weight: 800 kg
Specialities
With flexible extension elements
Ambient temperature
-52°C...+120°C, (-61°F...+248°F)
Process temperature
-52°C...+450°C (-61°F...+842°F)
Process pressure / max. overpressure limit
Characteristic / Application
Source container with flexible extension element to position up to 20 sources inside the process vessel (diptube) Weight: 800 kg
Ambient temperature
-52°C.…+120°C (-61°F.…+248°F)
Process temperature
-52°C.…+450°C (-61°F.…+842°F)
Specialities
With flexible extension elements
Most downloaded
BA Source container FQG74
English version - 11/2024
Radiometric level measurement
Language:
English
Version:
11/11/2024
File size:
33.5 MB
File name:
BA02365FEN_0324-00.pdf
TI Source container FQG74
English version - 12/2024
Radiometric level measurement
EN
DE ES FR IT JA PT RU ZH
16/12/2024
26/09/2024
Language:
English
Version:
16/12/2024
File size:
2.3 MB
File name:
TI01798FEN_0424-00.pdf
13 documents
TI Source container FQG74
Radiometric level measurement
EN
German Spanish French Italian Japanese Portuguese Russian Chinese
16/12/2024
26/09/2024
Language:
English
Version:
16/12/2024
File size:
2.3 MB
File name:
TI01798FEN_0424-00.pdf
BA Source container FQG74
Radiometric level measurement
Language:
English
Version:
11/11/2024
File size:
28.4 MB
File name:
BA02361FEN_0224-00.pdf
BA Source container FQG74
Radiometric level measurement
Language:
English
Version:
11/11/2024
File size:
33.5 MB
File name:
BA02365FEN_0324-00.pdf
Language:
English
Version:
14/03/2025
File size:
2.1 MB
File name:
EA01509FEN_0124-00.pdf
EA Sight glass of the cover with seal
Source Container FQG74
Language:
English
Version:
14/03/2025
File size:
756.8 KB
File name:
EA01508FEN_0124-00.pdf
EA Seal set
Shutter, hood, transportation lock
Source Container FQG74
Language:
English
Version:
14/03/2025
File size:
1.7 MB
File name:
EA01512FEN_0124-00.pdf
EA Sight glasses of the shutter with seal
Source Container FQG74
Language:
English
Version:
14/03/2025
File size:
712.8 KB
File name:
EA01506FEN_0124-00.pdf
SD Source container FQG74
Loading, unloading and replacing radiation sources
Language:
English
Version:
21/02/2025
File size:
3.8 MB
File name:
SD03387FEN_0125-00.pdf
SD Source container FQG74
Loading, unloading and replacing radiation sources Label set
Language:
English
Version:
31/10/2024
File size:
3.8 MB
File name:
SD03325FEN_0124-00.pdf
Returning: Source containers, radiation sources
EN
German
19/02/2025
19/06/2020
31/10/2017
11/12/2010
23/03/2010
Language:
English
Version:
19/02/2025
File size:
9.5 MB
File name:
SD00309FEN_1625-00.pdf
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .
Customize
Accept only essential
Accept all