Imperial temperature sensor without thermowell

iTHERM ModuLine TM112
Industrial modular thermometer

Imperial RTD/TC direct contact thermometer for a wide range of industrial applications

TM112
Please Wait (spinning wheel)
Loading price
Prices temporarily unavailable
Price on request
activating price
price: provide information
Filter Measuring / Application task
Measuring / Application task

Configure to download the CAD drawings of this product

  • Measuring principle

    Resistance Temperature Detector

  • Characteristic / Application

    imperial style
    universal range of application
    suitable for hazardous areas
    can be used with iTHERM StrongSens, iTHERM QuickSens
    direct process contact

  • Thermowell / protection tube

    without, direct process contact

  • Insert / probe

    mineral insulated (MI), flexible

  • Outer diameter protection tube / Insert

    Insert:
    1/8"
    1/4"
    3/8"
    3/8" reduziert auf 3/16"
    3,0 mm
    6,0 mm

  • Max. immersion length on request

    up to 180"

  • Material protection tube/ thermowell

    Insert Material:
    316L (1.4404)
    Alloy 600 (2.4816)

  • Process connection

    Thread:
    NPT1/2", NPT3/4"
    Compression fitting, also spring load:
    NPT1/4", NPT1/2"

  • Tip shape

    straight
    stepped

  • Surface roughness Ra

    0,76 μm (30 μin.)
    1,6 μm (63,0 μin.)

  • Operating temperature range

    PT100 TF iTHERM StrongSens:
    -50 °C ...500 °C
    (-58 °F ...932 °F)
    PT100 TF iTHERM QuickSens:
    -50 °C …200 °C
    (-58 °F …392 °F)
    PT100 WW:
    -200 °C ...600 °C
    (-328 °F ...1.112 °F)
    PT100 basic TF:
    -50 °C ...200 °C
    (-58 °F ...392 °F)
    Typ K:
    max. 1.100 °C
    (max. 2.012 °F)
    Typ J:
    max. 800 °C
    (max. 1.472 °F)
    Typ N:
    max. 1.100 °C
    (max. 2.012 °F)

  • Max. process pressure (static)

    depending on the configuration

  • Accuracy

    Class AA acc. to IEC 60751
    Class A acc. to IEC 60751
    Class B acc. to IEC 60751
    Class special or standard acc. to ASTM E230
    Class 1 or 2 acc. to IEC 60584-2

  • Response time

    t90 starting at < 1,5 s iTHERM QuickSens
    depending on configuration

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    ATEX
    CSA C/US
    INMETRO
    ATEX IECEx

  • Certification

    SIL (Transmitter)