Successor
Memosens 2.0 pH electrode for demanding applications in the chemical and process industries
Read more
Simple products
Easy to select, install and operate
Technical excellence
Simplicity
Standard products
Reliable, robust and low-maintenance
Technical excellence
Simplicity
High-end products
Highly functional and convenient
Technical excellence
Simplicity
Specialized products
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections
Technical excellence
Simplicity
Fundamental selection
Meet your basic measurement needs
Technical excellence
Simplicity
Lean selection
Handle your core processes easily
Technical excellence
Simplicity
Extended selection
Optimize your processes with innovative technologies
Technical excellence
Simplicity
Xpert selection
Master your most challenging applications
Technical excellence
Simplicity
Application
Chemical industry, organic chemicals, power stations, food industry, laboratory measurements
Characteristic
Analog or digital pH electrodes for process engineering with ceramic diaphragm and KCl liquid electrolyte
Measuring principle
Liquid-KCl with ceramic diaphragm
Design
All shaft lengths with temperature sensor Digital electrode with Memosens technology
Dimension
Diameter: 12 mm (0.47 inch) Shaft length: 120, 225, 360 and 425 mm (4.72, 8.86, 14.17 and 16.73 inch)
Process temperature
0 to 135 °C (32 to 275 °F)
Process pressure
1 to 11 bar abs (15 to 160 psi)
Connection
Contactless, inductive, digital connection head with Memosens technology
Additional certifications
Most downloaded
pH/ORP sensors and reference half cells
English version - 05/2020
Sensors with Memosens technology and analog sensors
EN
BG CS DA DE EL ES ET FI FR HR HU ID IT JA KO LT LV NL NO PL PT RO RU SK SL SV TH TR ZH
More
04/05/2020
31/12/2017
30/11/2015
Language:
English
Version:
04/05/2020
File size:
1.1 MB
File name:
BA01572CEN_0320.pdf
39 documents
Orbisint CPS11D and CPS11
pH sensor for standard applications in process technology and environmental engineering
EN
Bulgarian German Spanish Finnish French Hungarian Italian Japanese Dutch Polish Portuguese Russian Chinese
Select other language
16/07/2021
31/10/2015
01/02/2008
01/11/2004
01/03/2004
Language:
English
Version:
16/07/2021
File size:
977.4 KB
File name:
TI00028CEN_1520.pdf
Technical Information CPS41, CPS41D
pH electrodes, analogue and digital with Memosens technology, with ceramic diaphragm and liquid KCl electrolyte, also with integrated temperature sensor
EN
German Spanish French Hungarian Italian Dutch Polish Russian Chinese
Select other language
07/01/2015
01/03/2005
01/10/2002
01/05/2002
01/07/1998
Language:
English
Version:
07/01/2015
File size:
406.4 KB
File name:
TI00079CEN_1315.pdf
pH/ORP sensors and reference half cells
Sensors with Memosens technology and analog sensors
EN
Bulgarian Czech Danish German Greek Spanish Estonian Finnish French Croatian Hungarian Indonesian Italian Japanese Korean Lithuanian Latvian Dutch Norwegian Polish Portuguese Romanian Russian Slovak Slovenian Swedish Thai Turkish Chinese
Select other language
04/05/2020
31/12/2017
30/11/2015
Language:
English
Version:
04/05/2020
File size:
1.1 MB
File name:
BA01572CEN_0320.pdf
Memosens pH/ORP
Sicherheitshinweise für elektrische Betriebsmittel im
explosionsgefährdeten Bereich
Safety instructions for electrical apparatus for explosion-hazardous
areas
Conseils de sécurité pour matériels électriques destinés aux zones
explosibles
Safety Instructions
Safety instructions for electrical apparatus for explosion-hazardous areas
EN
German French
Select other language
11/11/2016
31/12/2011
01/04/2009
Language:
English
Version:
11/11/2016
File size:
3.7 MB
File name:
XA00079CA3_1416.pdf
Memosens pH/ORP
Sicherheitshinweise für elektrische Betriebsmittel im
explosionsgefährdeten Bereich
Safety instructions for electrical apparatus for explosion-hazardous
areas
Conseils de sécurité pour matériels électriques destinés aux zones
explosibles
Safety Instructions
Safety instructions for electrical apparatus for explosion-hazardous areas
EN
German French Polish
Select other language
22/02/2016
04/03/2015
14/01/2013
21/10/2010
01/12/2006
Language:
English
Version:
22/02/2016
File size:
4.3 MB
File name:
XA00376CA3_1616.pdf
pH and ORP measurement Supplement to: BA01572C, BA01109C Safety instructions for electrical equipment in explosion-hazardous areas EAC Ex 0Ex ia IIC T3/T4/T6 Ga X EAC Ex 0Ex ia IIC T4/T6 Ga X
EN
German Russian
Select other language
01/03/2022
18/02/2021
08/03/2016
Language:
English
Version:
01/03/2022
File size:
508.1 KB
File name:
XA01437CEN_0322-00.pdf
pH/ORP measurement Supplement to BA01572C, BA01109C Safety instructions for electrical apparatus in explosion-hazardous areas UKEx II 1 G Ex ia IIC T3/T4/T6 Ga UK Ex II 1 G Ex ia IIC T4/T6 Ga
Language:
English
Version:
08/12/2021
File size:
435.2 KB
File name:
XA02786CEN_0121-00.pdf
Äußere Kennzeichnung von digitalen Sensoren und Kabeln mit Memosens-Technologie
EN
German French
Select other language
01/03/2007
Language:
English
Version:
01/03/2007
File size:
284.4 KB
File name:
SD124Ca2.pdf
Kurzanleitung pH-/Redox-Sensoren - Short Instructions pH/ORP sensors
pH-/Redox-Sensoren - pH/ORP sensors
EN
Czech German Finnish Polish
Select other language
01/04/2007
01/09/1999
Language:
English
Version:
01/04/2007
File size:
361.7 KB
File name:
SD050Ca2.pdf
Adapting existing KCl supplies to new CPS4x/CPS441 Umstellen bestehender KCl-Zufuhr auf neue CPS4x/CPS441
EN
German
Select other language
27/05/2015
Language:
English
Version:
27/05/2015
File size:
271.2 KB
File name:
SD00105CA2_0105.pdf
5 spare parts & accessories
5 spare parts
5 accessories
Kit CPSxx protective caps
Memoclip label Memosens sensor
KCL-Electrolyte solution CPY4
Technical buffer solution CPY20
Elektrolyte reservoir CPY7B
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .
Customize
Accept only essential
Accept all